Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527823

RESUMO

ABSTRACT Purpose: To present long-term results of pars plana vitrectomy combined with pan-retinal endolaser photocoagulation, Ahmed glaucoma valve implantation, and/or phacoemulsification in patients with complicated neovascular glaucoma. Methods: The study comprised 15 eyes from 15 patients with neovascular glaucoma as a complication of diabetic retinopathy and owing to ischemic central retinal vein occlusion. There was a vitreous hemorrhage n all of the patients. Furthermore, 8 of the cases showed varying degrees of hyphema. All subjects received an intravitreal injection of bevacizumab three days before surgery. In 12 phakic patients, phacoemulsification, pars plana vitrectomy, and Ahmed glaucoma valve implantation were performed. Pars plana vitrectomy and Ahmed glaucoma valve implantation were performed in 3 pseudophakic patients. Perioperative and postoperative complications, intraocular pressure values, and best-corrected visual acuity scores were also recorded. Results: The mean follow-up was 24.4 ± 14.56 months. The mean preoperative intraocular pressure was 50.06 ± 7.6 mmHg. At 1 day, 7 days, and 1-, 3-, 6-, 12-month, and last visit following surgery, the mean intraocular pressure was 11.06 ± 8.22, 12.66 ± 7.27, 13.8 ± 7.73, 18.64 ± 7.05, 19.28 ± 4.61, 16.28 ± 1.68, and 16.92 ± 2.12 mmHg, respectively (p=0.001 for every follow-up visit). The mean visual acuity on the most recent appointment was 1.18 ± 0.42 logMar (p=0.001 for each subsequent visit). As postoperative early complications, varying degrees of hyphema and fibrin reactions were recorded. During follow-up, one patient developed phthisis bulbi. In 4 cases, Ahmed glaucoma valve revision surgery was required. Conclusions: In patients with complicated neovascular glaucoma, combined surgical procedures are safe, effective, and preferable both in terms of controlling high intraocular pressure and providing reasonable visual abilities.


RESUMO Objetivo: Apresentar nossos resultados de longo período de vitrectomia pars plana combinada com fotocoagulação panretiniana com endolaser, implantação da válvula Ahmed para glaucoma e/ou facoemulsificação em pacientes com glaucoma neovascular complicado. Métodos: Foram incluídos no estudo 15 olhos de 15 pacientes com glaucoma neovascular como complicação da retinopatia diabética e devido à oclusão isquêmica da veia central da retina. Todos os casos tiveram hemorragia vítrea. Além disso, 8 dos casos apresentaram diferentes graus de hifema. A injeção intravítrea de bevacizumabe foi administrada em todos os casos 3 dias antes da cirurgia. Facoemulsificação, vitrectomia pars plana e implantação da válvula Ahmed para glaucoma foram realizadas em 12 pacientes fáquicos. A vitrectomia pars plana e a implantação da válvula Ahmed para glaucoma foram realizadas em 3 pacientes pseudofáquicos. Complicações perioperatórias e pós-operatórias, valores de pressão intraocular e valores de melhor acuidade visual corrigida pré-operatório e pós-operatório foram registrados. Resultados: O acompanhamento médio foi de 24,4 ± 14,56 meses. A média da pressão intraocular pré-operatória foi de 50,06 ± 7,6 mmHg. Em 1 dia, 7 dias e 1,3,6,12 meses, e última visita após cirurgia, a média da pressão intraocular foi de 11,06 ± 8,22, 12,66 ± 7,27, 13,8 ± 7,73, 18,64 ± 7,05, 19,28 ± 4,61, 16,28 ± 1,68 e 16,92 ± 2,12 mmHg, respectivamente (p=0,001 para cada visita de acompanhamento). A média da acuidade visual na última visita foi de 1,18 ± 0,42 logMar (p=0,001 para cada visita de acompanhamento). Vários graus de reações de hifema e fibrina foram registrados como complicações precoces pós-operatórias. Phthisis bulbi foi desenvolvido em um caso durante o acompanhamento. A cirurgia de revisão da válvula Ahmed para glaucoma foi necessária em 4 casos. Conclusões: Os procedimentos cirúrgicos combinados que realizamos são seguros, eficazes e preferenciais, tanto em termos de controle da alta pressão intraocular quanto fornecimento de habilidades visuais razoáveis em pacientes com glaucoma neovascular complicado.

2.
Arq. bras. oftalmol ; 87(3): e2023, 2024. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1550033

RESUMO

ABSTRACT Purpose: This study aims to compare the initial ocular discomfort symptoms resulting from trabeculectomy and Ahmed glaucoma valve implantation surgeries. Methods: A prospective comparative study was conducted. The evaluation of ocular discomfort employed a questionnaire designed to identify the frequency and severity of distinct symptoms: ocular pain, general discomfort, tearing, foreign body sensation, and burning. This questionnaire was administered prior to surgery as a baseline, and subsequently at 7, 30, and 90 days post-surgery. Simultaneously, the Ocular Surface Disease Index (OSDI) was applied at these same time intervals. Results: The study encompassed a total of 17 patients (9 undergoing trabeculectomy and 8 undergoing Ahmed glaucoma valve implantation). The Ahmed glaucoma valve implantation group exhibited higher tearing levels at baseline (p=0.038). However, no statistically significant differences in symptoms were observed between the two surgeries at 7 and 30 days post-surgery. At the 90-day mark following surgery, patients who had undergone trabeculectomy reported a significantly higher foreign body sensation (p=0.004). Although OSDI scores did not differ between groups at baseline, the trabeculectomy group showed significantly higher OSDI scores than the Ahmed glaucoma valve implantation group at 7, 30, and 90 days after surgery (p<0.05). Conclusion: Post-surgery, patients who had undergone trabeculectomy experienced increased foreign body sensation. Trabeculectomy appears to cause greater early postoperative ocular discomfort compared to the Ahmed glaucoma valve implantation group.

3.
Ophthalmol Ther ; 12(5): 2381-2395, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37558818

RESUMO

Glaucoma remains a leading cause of blindness globally. Minimally invasive treatment techniques are rapidly expanding the availability of therapeutic options for glaucoma. These include devices aimed at enhancing outflow through the subconjunctival space, Schlemm's canal, and suprachoroidal space, sustained-release drug delivery devices, and extraocular devices aiming to reduce glaucomatous progression through other novel means. In this review, we provide an overview of several novel devices either newly available or in development for the medical and surgical management of glaucoma. Further studies are required to determine the long-term efficacy of these devices and how they will integrate into the current landscape of glaucoma management.

4.
J Curr Glaucoma Pract ; 17(2): 98-103, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37485463

RESUMO

Purpose: To evaluate the demographic composition of academic glaucoma specialists currently practicing in the United States. Design: Retrospective and observational study. Subjects: Academic glaucoma specialists identified from ophthalmology residency programs listed on the Doximity database. Methods: The American Board of Ophthalmology (ABO) membership directory, Doximity database, publicly available data, and direct communications were used to identify academic glaucoma specialists and their demographics. Information collected included-name, gender, race/ethnicity, geographic location, board certification date, academic affiliation, and academic rank. Ophthalmic age was defined as the number of years since ophthalmology board certification. Underrepresented minority (URM) groups were defined as Hispanics, Black or African Americans, Latinos, American Indians, or Alaskan Natives as defined by San Francisco match. In addition, the temporal, geographic, and academic rank distributions among females and URMs were explored. Main outcome measures: Women and URMs representations among academic glaucoma specialists across academic ranks, geographic regions, as well as ophthalmic age. Results: There were 457 active academic glaucoma specialists identified from 110 institutions in 38 states. Among them, 185 (40.5%) were women and 42 (9.2%) were URM. The proportion of women glaucoma specialists in academia had increased significantly with a rate of 1.049 in odds ratio (OR) per year (p < 0.001). However, there were no significant changes in the proportion of URMs over time. The earliest year of certification was 1,964 for males and 1,974 for females. When controlled for ophthalmic age, there were no significant differences in the distribution of women or URMs between the different academic ranks (p = 0.572 and p = 0.762, respectively). Among assistant professors, women had a significantly higher ophthalmic age compared to men (p < 0.001), but there was no significant difference in ophthalmic age in both the associate and full professor groups. There were no significant differences in the geographic distribution of gender (p = 0.516) and URM across United States regions (p = 0.238). Conclusion: The proportion of women among academic glaucoma specialists has significantly increased over the past 5 decades; however, the proportion of URMs has been stagnant in the same period. Enhancing URM representation among academic glaucoma specialists deserves to be a future priority. How to cite this article: Afzali K, Fujimoto DK, Mohammadi SO, et al. Race and Gender Shift among Academic Glaucoma Specialists in the Last 5 Decades. J Curr Glaucoma Pract 2023;17(2):98-103.

5.
Korean J Ophthalmol ; 37(3): 216-223, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37309554

RESUMO

PURPOSE: To evaluate the effect of intraoperative mitomycin C (MMC) on the surgical outcomes of ciliary sulcus (CS) Ahmed glaucoma valve (AGV) tube placement. METHODS: A retrospective review of medical records of 54 consecutive patients who underwent AGV implantation with tube placed in CS was performed. Consecutive cases operated without the use of intraoperative MMC from 2017 to 2019 were compared with consecutive cases operated with MMC from 2019 to 2021. Surgical failure was defined as intraocular pressure (IOP) exceeding 21 mmHg in two consecutive visits after postoperative 3 months or ≤30% IOP reduction, IOP ≤5 mmHg in two consecutive visits, or loss of light perception. Kaplan-Meier survival analysis and log-rank test were performed to compare the surgical failure rates. RESULTS: A total of 54 eyes of 54 patients were investigated. Mean follow-up period after AGV implantation was 1.4 ± 0.8 years. The MMC group showed significantly lower IOP during the 1st postoperative month (20.5 ± 8.6 mmHg vs. 15.8 ± 6.4 mmHg, p = 0.027), but the difference did not persist 6 months after the surgery (p = 0.805). The mean number of postoperative antiglaucoma medications was significantly lower in the MMC group in the 1st postoperative month (p = 0.047) but no difference was found at 6 months. No statistical difference was noted in the rates of postoperative complications. Kaplan-Meier survival analysis showed comparable survival rates between MMC group and no MMC group (p = 0.356). CONCLUSIONS: The intraoperative use of MMC significantly lowered IOP in the 1st postoperative month but did not increase 6 months success rates in patients receiving AGV tube placement in CS.


Assuntos
Glaucoma , Hipotensão Ocular , Humanos , Mitomicina , Pressão Intraocular , Olho , Resultado do Tratamento
6.
J Ophthalmic Vis Res ; 18(2): 150-156, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37181616

RESUMO

Purpose: To evaluate the effect of phacoemulsification on intraocular pressure (IOP) in eyes with functioning tube shunts. Methods: This was a retrospective chart review of primary open-angle glaucoma (POAG) patients with a functioning tube who underwent phacoemulsification and had ≥24 months of follow-up. The primary end point was defined as surgical failure (IOP > 21 mmHg) at month 24, progression to no light perception (NLP) vision, glaucoma reoperation, or implant removal. Surgical failure defined as IOP >18 and >15 mmHg, changes in visual acuity (VA), IOP, and number of medications were assessed. Results: Twenty-seven eyes of 27 patients with moderate or severe POAG were included. The mean age of the patients was 64.2 ± 10.8 years. The interval between the tube shunt and phacoemulsification was 28.8 ± 25.0 months. At the end of the study, four (14.8%) eyes met the failure criteria; the average time to failure was 9.3 ± 3.8 months. The causes of failure were high IOP in two (50.0%) and glaucoma reoperation in two (50.0%) eyes; however, no eyes progressed to NLP vision. Surgical failure defined as IOP >18 and >15 mmHg showed an increasing failure rate (18.5% and 48.5%, respectively).Themean IOP and medications number remained stable at month 24 compared to baseline (P = 0.131 and P = 0.302, respectively). Initially, VA showed improvement, with the greatest improvement at 6 months (P = 0.001), but at 24 months the improvement was no longer significant (P = 0.430). Conclusion: Phacoemulsification in patients with functioning tubes did not change the mean IOP in most of the patients (86.2%); the number of medications also did not increase.

7.
Arq. bras. oftalmol ; 86(6): e20230073, 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520203

RESUMO

ABSTRACT This is a case report involving a 56-year-old male patient with a history of pars plana vitrectomy due to a rhegmatogenous retinal detachment in the right eye that resulted in the implantation of a drainage device after the patient developed secondary glaucoma. Two years after the device's implantation, the patient was referred to our care as his visual acuity had decreased to 20/200 (1.00 LogMAR). At the fundus evaluation, a choroidal amelanotic elevation was observed at the upper temporal equator, and a potential diagnosis was made of amelanotic choroidal melanoma. The ultrasound exam visualized the patient's implanted superotemporal justabulbar drainage device, which revealed a transscleral communication from the plate fibrocapsular's draining space to the suprachoroidal space (fistula). The ultrasound also revealed a focal pocket of choroidal detachment in the patient's superotemporal region, simulating an amelanotic choroidal melanoma. A new pars plana vitrectomy was performed to remove the internal limiting membrane without repercussions at the fistula site. The patient's recovery progressed well, and he regained a visual acuity of 20/70 (0.55 LogMAR). To the best of our knowledge, this is the first case report of this condition.


RESUMO Relato de caso de paciente 56 anos, sexo masculino, com histórico de vitrectomia via pars plana por descolamento de retina em olho direito e posterior implante de dispositivo de drenagem por glaucoma secundário. Dois anos após o procedimento foi encaminhado ao serviço por baixa de acuidade visual (AV) de 20/200 (1.00 LogMAR). À fundoscopia, observou-se uma elevação amelanótica temporal no equador com hipótese diagnóstica de melanoma de coroide amelanótico. O exame de ultrassom mostrou implante de dispositivo de drenagem justabulbar temporal superior com comunicação transescleral para espaço subcoroidal (fístula), sugerindo bolsão focal de descolamento de coroide em equador temporal superior simulando melanoma de coroide amelanótico. O paciente foi abordado cirurgicamente devido membrana epirretiniana com nova vitrectomia via pars plana para peeling de membrana limitante interna, sem repercussões no local da fístula, evoluindo bem com acuidade visual de 20/70 (0.55 LogMAR). Ao nosso conhecimento, este é o primeiro caso relatado nessa condição.

8.
International Eye Science ; (12): 1461-1465, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-980533

RESUMO

AIM: To preliminarily evaluate the efficacy and safety of XEN drainage tube implantation in the treatment of refractory glaucoma.METHODS: The clinical data of 10 patients(11 eyes)with refractory glaucoma who underwent XEN gel drainage tube implantation in Peking University Third Hospital from September 2021 to January 2022 were retrospectively analyzed. All patients were followed-up for 8-12mo after surgery, the intraocular pressure(IOP)and the use of IOP lowering medication were observed, and the effect of the surgery was evaluated.RESULTS: The highest IOP was 21-55(median 35)mmHg before surgery and 10-40(median 15)mmHg at the last follow-up. There were 2-4(median 4)kinds of IOP lowering drugs before operation and 0-4(median 0)kinds of IOP lowering drugs at the last follow-up. Up to the last follow-up, the surgery was successful in 8 eyes and unsuccessful in 3 eyes.CONCLUSION: Implantation of XEN gel drainage tube is a safe and effective method for the treatment of refractory glaucoma.

9.
International Eye Science ; (12): 1603-1608, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-987876

RESUMO

AIM: To investigate the safety and efficacy of Paul glaucoma implant(PGI)in the short-term follow-up period and share first experience with this novel aqueous shunt in Indonesian populations.METHODS: A total of 21 patients(22 eyes)with PGI implants from April 2022 to December 2022 and with at least a complete 2mo follow-up were retrospectively analyzed. The primary outcome measure was failure, defined as intraocular pressure(IOP)out of the target range of 21 mmHg or less than 20% reduction from baseline for 2 consecutive visits, other glaucoma surgeries required, or removal of the implant.RESULTS: The follow-up period was 2 to 6mo. The mean IOP reduction was 52.27±22.94%, with a range of 9% to 90%. The complete success rate was 59%, and patients with or without a history of glaucoma surgery had 50% and 59% of complete success rates, respectively. Complications of the surgery were diplopia(n=2), early hypotony(n=1), hyphema(n=1), and exposed tube(n=2).CONCLUSION: The complete success of the PGI implantation was 57%. No serious postoperative complications were found in our cases. One case of hypotony resolved in the early postoperative period.

10.
J Curr Glaucoma Pract ; 16(2): 74-78, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36128084

RESUMO

Purpose: The study purpose was to assess patient survival after tube shunt implant or cyclodestructive procedure for neovascular glaucoma and to determine whether specific preoperative factors are predictive of survival. Materials and methods: A retrospective chart review was performed on patients with neovascular glaucoma who underwent tube shunt implant and/or cyclodestructive procedure between January 2002 and December 2019 at the Minneapolis Veterans Affairs Health Care System. Patient survival was compared to the age and gender-matched Minnesota population. Cox regression analyses were performed to evaluate preoperative parameters and survival. Results: Tube shunt alone was implanted in 30 eyes, cyclodestruction alone was performed in nine eyes, and two eyes underwent both (n = 41 eyes, 39 patients). The postoperative 5-year survival rate was 62% in neovascular glaucoma patients compared to 80% in controls. Survival did not differ significantly based on neovascular glaucoma etiology. Preoperative best-corrected visual acuity of the neovascular glaucoma-affected eye (p = 0.05) and Charlson Comorbidity Index (p = 0.02) were associated with survival, but preoperative maximum intraocular pressure, hemoglobin A1c, and creatinine were not. The mean intraocular pressure at 6 months postprocedure was 14 mm Hg for tube shunt and 27 mm Hg for cyclodestruction (p = 0.03). Conclusion: Neovascular glaucoma patients have reduced survival, but the majority survived at least 5-year postprocedure. Ophthalmologists should consider patient survival and factors predictive of survival when planning procedures for neovascular glaucoma. Clinical significance: Our findings provide an updated perspective on survival in the setting of neovascular glaucoma and can help ophthalmologists provide patient-centered and holistic care. How to cite this article: Zhou Y, Coleman S, Boysen J, et al. Survival in Patients with Neovascular Glaucoma Following Tube Shunt Implant or Cyclodestructive Procedure. J Curr Glaucoma Pract 2022;16(2):74-78.

11.
Ophthalmologie ; 119(Suppl 2): 140-146, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34698908

RESUMO

Recent years have seen a trend towards change in glaucoma treatment. In addition to classic trabeculectomy, implant surgeries such as those based on the Baerveldt, Ahmed and Molteno devices are increasingly performed as a primary procedure. This is doubtless partly due to the fact that surgeons have become more comfortable with the use of tube shunts and their postoperative management. The aim of this article is to present the currently available evidence on glaucoma surgery in a succinct format, to enable the best possible decisions to be made for patients.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Trabeculectomia , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Esclera
12.
Rev. bras. oftalmol ; 81: e0041, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1387975

RESUMO

ABSTRACT Glaucoma drainage devices are important therapeutic options for cases of refractory glaucoma, in which trabeculectomy with antimetabolites has shown high risk of failure. There are devices with different sizes, designs and materials, and several studies have been conducted to test their safety and effectiveness. Despite known complications, their use has progressively increased in recent years, and they are the primary surgical option, in some situations. The aim of this review is to discuss the importance, mechanisms, biomaterials, results and complications of glaucoma drainage devices.


RESUMO Os dispositivos de drenagem para glaucoma são importante opção terapêutica em casos de glaucomas refratários, nos quais a trabeculectomia com antimetabólitos tem alta chance de falência. Há dispositivos com diferentes tamanhos, desenhos e materiais, e muitos estudos foram realizados para testar sua segurança e eficácia. Apesar de suas conhecidas complicações, seu uso tem aumentado progressivamente nos últimos anos, inclusive como primeira opção cirúrgica, em algumas situações. O objetivo desta revisão foi discutir a importância, os mecanismos, os biomateriais, os resultados e as complicações dos dispositivos de drenagem para glaucoma.


Assuntos
Humanos , Glaucoma/cirurgia , Cirurgia Filtrante/instrumentação , Implantes para Drenagem de Glaucoma , Materiais Biocompatíveis , Glaucoma/fisiopatologia , Cirurgia Filtrante/métodos , Implantação de Prótese , Pressão Intraocular/fisiologia
14.
J Curr Glaucoma Pract ; 15(1): 44-46, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34393457

RESUMO

Tube retraction after Ahmed glaucoma valve (AGV) implantation is an infrequent but known complication. The management option includes the use of a commercially available AGV tube extender, 22 G angiocatheter, resisting the existing glaucoma drainage device (GDD), or insertion of a new GDD. Each of the methods described in the literature has its limitations. We describe the successful management of this complication by using a cost-effective technique of connecting the silicone tube segment to the existing tube to lengthen the tube, so that it could be inserted in the anterior chamber again. The silicone tubes used for the technique were the extra length of the GDD tube, which was cut short and leftover during other GDD implantation surgeries. CLINICAL SIGNIFICANCE: During any GDD implantation, the tube is cut short before entering the anterior chamber. We retrieved the short segments of the tube immediately after the GDD was opened on the table and sterilized them again using plasma technology, available in our operating room. Hence, it provides a cost-effective alternative since the tube is usually trimmed to the desired length in all cases of GDD implantation (valved/non-valved), which can be subsequently sterilized and reused for lengthening the short tube in cases with tube retraction or inadvertently cut tube. HOW TO CITE THIS ARTICLE: Pandav SS, Gautam N, Thattaruthody F. Tube-in-tube: A Solution for Retracted Tube. J Curr Glaucoma Pract 2021;15(1):44-46.

15.
Rom J Ophthalmol ; 65(2): 150-156, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34179580

RESUMO

Purpose: To investigate the implantation of Polytetrafluoroethylene (PTFE) as a glaucoma drainage device. Methods: This study has been done in two steps. First, the constructed implants have been used in 4 rabbits and the histopathologic response was evaluated. In the second step, the implants were used in the 6 eyes of 6 patients with end-stage glaucoma with uncontrolled IOP and poor visual acuity. The tube was made of two-layer of PTFE membrane measuring 8 * 6 mm with a thickness of 1.8 mm and a silicone tube. The rabbits and the human eyes underwent surgical implantation of the tube in the anterior chamber. The histopathologic evaluation was done using H&E staining. Visual acuity, intraocular pressure and the number of glaucoma medications were assessed before and after the surgery. Results: In the histopathologic evaluation, subconjunctival polarizing fibers of a synthetic mesh infiltrated by fibrovascular septa was seen. A granulomatous inflammatory reaction composed of histiocytes, lymphocytes, and multinucleated giant cells were seen around and between the synthetic bundles. The average age of patients was 63 ± 5.5 years. The mean IOP reached from 36.6 ± 5.7 mmHg at baseline to 16.2 ± 8.9 mmHg at the final follow-up. Patients were followed for an average of 6.6 ± 4.5 months. One patient found hypotony refractory to medical and surgical treatment, which led to implant removal. One patient had uncontrolled IOP and finally led to phthisis bulbi following slow CPC. The remaining four eyes did well during the follow-up. Conclusion: The use of PTFE as a new polymer in tube shunt construction was reported. Larger studies, modification of the PTFE membranes like changing the porosity amount, and size of PTFE membranes might result in different conclusions.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Animais , Seguimentos , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Projetos Piloto , Politetrafluoretileno , Coelhos , Estudos Retrospectivos , Resultado do Tratamento
16.
Clin Ophthalmol ; 15: 461-472, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33603323

RESUMO

PURPOSE: To investigate risk factors associated with success and failure in double-plate tube surgery. METHODS: This retrospective case-series observational study included 243 consecutive eyes that underwent anterior-segment double-plate tube surgery from 1990 to 2015. Evaluation of the efficacy of the device was based on the final intraocular pressure (IOP) and the need for anti-glaucoma medication. We also assessed success and failure according to risk factors for trabeculectomy and an early hypertensive phase (HP). RESULTS: Preoperative IOP was 37.3±13.1 mmHg (mean±SD) with 3.0±0.7 medications. After a median follow-up of 44.3 months, the mean IOP was 14.6±6.3 mmHg with 0.4±1.0 medications. The final IOPs ranged from 6 to 21 mmHg in 87.24% of eyes; however, 25.47% required medication. No risk factors studied were associated with surgical failure. Preoperative IOP, glaucoma type, previous surgery, previous anti-glaucoma drugs, implant type, and HP were associated with partial success (p<0.05). HP and preoperative use of brimonidine reduced the probability of complete success by 66.9% and 68.2%, respectively (p<0.05). HP was more likely when chronic preoperative prostaglandin analogues were administered (odds ratio [OR] 4.286; 95% confidence intervals [CI] 1.593-11.529; P=0.0039) and when the tube was located in the posterior chamber (OR 3.561; 95% CI 1.286-9.861; P=0.0145). CONCLUSION: Tube surgery is effective and seems to be independent of the major risk factors for glaucoma surgery. However, previous surgery and some chronic preoperative drugs are related to the need for glaucoma medication to achieve the target pressure.

17.
Korean J Ophthalmol ; 34(6): 446-453, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33307604

RESUMO

PURPOSE: To investigate the effect of head tilt on the tube position of the Ahmed glaucoma valve (AGV) implanted in patients with glaucoma and to assess how the head tilt-induced alterations of tube parameters and the level of tube entry influence corneal endothelial cell density (ECD). METHODS: A total of 29 eyes of 26 patients with AGV implantation were included. Tube-cornea distance, tube-cornea angle, and intracameral tube length were measured using anterior segment optical coherence tomography in three different head positions (neutral, 30° temporalward tilt, and 30° nasalward tilt). The tube entry was assessed using static gonioscopy. ECD was measured using specular microscopy before and after surgery. RESULTS: The mean tube-cornea distance, tube-cornea angle, and intracameral tube length (neutral: 0.87 ± 0.39 mm, 30.56 ± 5.89˚, and 3.10 ± 0.82 mm, respectively) decreased with head tilts (temporalward: 0.82 ± 0.39 mm, 29.27 ± 5.82˚, and 3.04 ± 0.82 mm, respectively; nasalward: 0.83 ± 0.40 mm, 29.61 ± 6.04˚, and 3.05 ± 0.81 mm, respectively; all p < 0.01). The multivariate analyses found age and the tube insertion level to be associated with postoperative changes in the central ECD (p = 0.039 and 0.013, respectively), and the postoperative follow-up period and tube insertion level to be associated with the difference between the inferonasal and superotemporal ECDs (p = 0.034 and 0.007, respectively). CONCLUSIONS: Mild alterations of head positions induced changes in the intracameral tube positions of AGV implants; nevertheless, it did not significantly affect ECD loss. However, the eyes with tubes inserted anteriorly to Schwalbe's line may be more susceptible to corneal ECD loss.


Assuntos
Células Endoteliais , Implantes para Drenagem de Glaucoma , Câmara Anterior/diagnóstico por imagem , Estudos Transversais , Humanos , Pressão Intraocular
18.
Rev. bras. oftalmol ; 79(6): 413-415, nov.-dez. 2020. graf
Artigo em Português | LILACS | ID: biblio-1156158

RESUMO

Resumo Descrevemos o caso de um paciente portador de glaucoma secundário que evoluiu com cisto de tenon após implante de válvula de Ahmed. A despeito da conduta expectante inicial e das intervenções cirúrgicas posteriores, apenas com a utilização da ciclofotocoagulação transescleral com laser micropulsado a pressão intraocular atingiu valores aceitáveis.


Abstract We describe the case of a patient with secondary glaucoma who developed tenon cyst after Ahmed valve implantation. Despite the initial expectant management and subsequent surgical interventions, only with the micropulse transecleral cyclophotocoagulation did the intraocular pressure reach acceptable values.


Assuntos
Humanos , Masculino , Adulto , Complicações Pós-Operatórias , Glaucoma/cirurgia , Cirurgia Filtrante , Implantes para Drenagem de Glaucoma/efeitos adversos , Cistos , Cápsula de Tenon , Pressão Intraocular
19.
Am J Ophthalmol Case Rep ; 20: 100947, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33024893

RESUMO

PURPOSE: To provide the first report of effective use of bilateral XEN Gel Stent implantation using an ab externo open-conjunctival approach designed to improve bleb function and meet the uniquely low intraocular pressure requirements of a Japanese patient with normal-tension glaucoma refractory to topical medical therapy. OBSERVATIONS: A 54-year-old phakic Japanese woman with severe normal-tension glaucoma on maximally tolerated medical therapy of four topical agents presented with above-goal intraocular pressures and new medication intolerances. She underwent bilateral ab externo open-conjunctival XEN Gel Stent implantation with tenectomy and sub-Tenon's injection of 40µg of mitomycin-C, which resulted in reduction of intraocular pressures by 41.2 and 28.6% to 10 and 10 mmHg in the right and left eyes, respectively at the most recent visit. Postoperatively, a diffuse filtering bleb with good morphology developed in both eyes. The procedure has so far allowed for complete cessation of all four topical medications for up to eight months following surgery without any serious complications. CONCLUSIONS: This case illustrates the potential of Xen Gel Stent implantation through an ab externo, open-conjunctival approach to be an effective, simple alternative to trabeculectomy to meet the unique low-pressure requirements of normal-tension glaucoma patients with practical and safety benefits of a micro-invasive approach.

20.
Rev. bras. oftalmol ; 79(4): 231-235, July-Aug. 2020. tab, graf
Artigo em Português | LILACS | ID: biblio-1137967

RESUMO

Resumo Objetivo: Segunda maior causa de cegueira mundial, o glaucoma, ocasionalmente necessita de procedimento cirúrgico para controle. Tendo o Brasil um Sistema Único de Saúde (SUS), e crise político-econômica em 2016, objetiva-se avaliar o impacto financeiro na decisão terapêutica do glaucoma nos últimos 6 anos no Brasil, e considerar atual discussão sobre indicação de procedimentos intervencionistas precocemente no seu algoritmo terapêutico. Métodos: Estudo ecológico da população brasileira, com base no Sistema de Informações Hospitalares do SUS, avaliando comportamento temporal dos procedimentos cirúrgicos do SUS para tratamento do glaucoma, e variação do dólar como influenciador da tendência temporal sobre os procedimentos. Realizada a análise de Regressão Linear Simples, com significância estatística de P<0.05. Resultados: Entre 2013 e 2018 foram internados 24888 indivíduos por glaucoma, prevalência do sexo masculino (51.68%), brancos (32,57%) e idosos (57.84%). Regiões Sudeste (45.61%) e Nordeste (26.36%) com maior número de internações, sendo a Trabeculectomia (84,18%) principal procedimento realizado. Houve associação da Trabeculectomia e Implante de Válvula, individualmente e atrelados, com os valores do dólar nas regiões Centro-Oeste (β= 1,103 com P= 0,007 para Trabeculectomias e β= 1,105 com P=0,012 para ambos os procedimentos) e Sul (β= 16,727 e P= 0,006 para os Implantes), e associação entre aumento de Implantes na região Sul e maior cobertura na atenção básica (β= 0.64 e P= 0.009). Conclusão: Observou-se não interferência do dólar, e aumento dos procedimentos na região Sul e Centro-Oeste. Os resultados corroboram tendência intervencionista, podendo ser representada pelo possível uso dos procedimentos disponibilizados pelo SUS de forma precoce.


Abstract Objective: The second leading cause of blindness worldwide, glaucoma, occasionally requires surgical procedure for control. Given that Brazil has an Unified Health System (SUS) and a political-economic crisis in 2016, we aim to evaluate the financial impact on the therapeutic decision of glaucoma in the last 6 years in Brazil, and to consider the current discussion about early interventionist indication in its therapeutic algorithm. Methods: Ecological study of the Brazilian population, based on the SUS Hospital Information System, evaluating the temporal behavior of SUS surgical procedures on glaucoma treatment, and dollar variation as influencing the temporal trend on the procedures. Simple Linear Regression analysis was performed, with statistical significance of P <0.05. Results: Between 2013 and 2018, 24888 individuals were hospitalized for glaucoma, male prevalence (51.68%), whites (32.57%) and elderly (57.84%). Southeast (45.61%) and Northeast (26.36%) Regions with the largest number of hospitalizations, and Trabeculectomy (84.18%) being the main procedure performed. There was an association of trabeculectomy and valve implantation, individually and linked, with dollar values in the Midwest (β = 1.103 with P = 0.007 for Trabeculectomies and β = 1.105 with P = 0.012 for both procedures) and South (β). = 16,727 and P = 0,006 for Implants), and association between increased Implants in the South region and greater coverage in primary care (β = 0.64 and P = 0.009). Conclusion: Non-dollar interference was observed, and increased procedures in the South and Midwest. The results corroborate an interventionist tendency and may be represented, possible, by the use of procedures provided by the SUS in an early manner.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Sistema Único de Saúde , Trabeculectomia/economia , Glaucoma/cirurgia , Implantação de Prótese/economia , Custos e Análise de Custo , Implantes para Drenagem de Glaucoma/economia , Brasil , Estudos Ecológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...